{"id":301,"date":"2020-10-27T11:44:41","date_gmt":"2020-10-27T11:44:41","guid":{"rendered":"https:\/\/dev.fluidotecnika.com\/?page_id=301"},"modified":"2022-06-13T14:41:34","modified_gmt":"2022-06-13T13:41:34","slug":"accessori","status":"publish","type":"page","link":"https:\/\/www.fluidotecnika.com\/en\/accessori\/","title":{"rendered":"Components for industry"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"301\" class=\"elementor elementor-301\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-b66d093 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b66d093\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-878f1f1\" data-id=\"878f1f1\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a35c2ef elementor-widget elementor-widget-heading\" data-id=\"a35c2ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Components for industry<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e45b80 elementor-widget elementor-widget-text-editor\" data-id=\"0e45b80\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\tTemperature, pressure, conductivity, conductivity sensors for machine tools and systems in the food, pharmaceutical, chemical and all automation sectors.\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-36b21a0 elementor-hidden-phone elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"36b21a0\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-674861a\" data-id=\"674861a\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-85de96a elementor-tabs-view-vertical elementor-widget elementor-widget-tabs\" data-id=\"85de96a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-tabs\">\n\t\t\t<div class=\"elementor-tabs-wrapper\" role=\"tablist\" >\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1401\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"true\" data-tab=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"elementor-tab-content-1401\" aria-expanded=\"false\">Temperature probes<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1402\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1402\" aria-expanded=\"false\">Smartflow<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1403\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1403\" aria-expanded=\"false\">CW510L<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1404\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"4\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1404\" aria-expanded=\"false\">Electronic flow regulators<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1405\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"5\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1405\" aria-expanded=\"false\">Conductivity sensors<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1406\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"6\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1406\" aria-expanded=\"false\">Pressure sensors<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1407\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"7\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1407\" aria-expanded=\"false\">Manometers<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1408\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"8\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1408\" aria-expanded=\"false\">Couplings - Quick couplings<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1409\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"9\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1409\" aria-expanded=\"false\">AISI 316L flow regulators<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-14010\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"10\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-14010\" aria-expanded=\"false\">Non-return valves in 316L stainless steel<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t<div class=\"elementor-tabs-content-wrapper\" role=\"tablist\" aria-orientation=\"vertical\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"true\" data-tab=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"elementor-tab-content-1401\" aria-expanded=\"false\">Temperature probes<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1401\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1401\" tabindex=\"0\" hidden=\"false\"><h2>ITS Inline Temperature Sensor<\/h2>\n<b>Features<\/b>\n<ul>\n \t<li>PPSU body<\/li>\n \t<li>Seal material FPM or EPDM (FDA compliant)<\/li>\n \t<li>Probe material Al2 O3<\/li>\n \t<li>Existing sensor types: Pt 100; NTC 10k; NTC 47k,<\/li>\n \t<li>Other types of sensors and thermocouples on request<\/li>\n \t<li>ELSA fitting connection for 6 or 4 mm pipe<\/li>\n \t<li>Operating pressure up to PN 20<\/li>\n \t<li>Fluid temperature up to 135 \u00b0C (NSF approval at 100 \u00b0C)<\/li>\n<\/ul>\n<img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-1303\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sonda-di-temperatura.jpg\" alt=\"\" width=\"589\" height=\"870\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sonda-di-temperatura.jpg 589w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sonda-di-temperatura-203x300.jpg 203w\" sizes=\"(max-width: 589px) 100vw, 589px\" \/><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1402\" aria-expanded=\"false\">Smartflow<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1402\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1402\" tabindex=\"0\" hidden=\"hidden\"><h2>Smartflow<\/h2><p>Pump with an innovative concept<\/p><p><a href=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min.png\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"wp-image-2632 size-medium alignnone\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-300x213.png\" alt=\"AVS Roemer Smartflow\" width=\"300\" height=\"213\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-300x213.png 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-1024x726.png 1024w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-768x545.png 768w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-1536x1090.png 1536w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-18x12.png 18w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-1320x936.png 1320w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-600x426.png 600w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min.png 1920w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a> <a href=\"https:\/\/www.fluidotecnika.com\/en\/smartflow-2\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"alignleft wp-image-2633 size-medium\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2-300x214.png\" alt=\"AVS Roemer Smartflow\" width=\"300\" height=\"214\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2-300x214.png 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2-1024x732.png 1024w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2-768x549.png 768w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2-18x12.png 18w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2-1320x943.png 1320w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2-600x429.png 600w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2.png 1440w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p><h3>Features<\/h3><ul><li>Excellent chemical resistance<\/li><li>Drive with specially developed BLDC motor<\/li><li>Absence of dead spaces that would encourage the formation of unwanted bacteria<\/li><li>Prevents microbiological buildup and growth<\/li><li>Maintenance-free, durable, reliable<\/li><li>Tight seal ensures wear-free operation and prevents leakage<\/li><\/ul><h3>Applications<\/h3><ul><li>Machines and plants for food beverages<\/li><li>Medical industry<\/li><li>Industry<\/li><\/ul><p><a href=\"https:\/\/www.avs-roemer.de\/media\/service\/produktkatalog-broschueren\/AVS_R%C3%B6mer_Produktflyer_Au%C3%9Fenzahnradpumpe_smartflow.pdf\" target=\"_blank\" rel=\"noopener\"><strong>DOWNLOAD DATA SHEET<\/strong><\/a><\/p><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1403\" aria-expanded=\"false\">CW510L<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1403\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1403\" tabindex=\"0\" hidden=\"hidden\"><h2>Components in CW510L low lead brass<\/h2>\n<h3>Main advantages<\/h3>\n<ul>\n \t<li>NSF 169 and NSF 61, 1935\/2004 \/ CE, DM 174<\/li>\n \t<li>Instant connection and disconnection<\/li>\n \t<li>Full passage and vacuum seal thanks to shaped gaskets<\/li>\n \t<li>Two types of threads, BSPP, BSPT<\/li>\n \t<li>Wide range available to satisfy the most demanding installations<\/li>\n \t<li>Silicon Free<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<ul>\n \t<li>Agri-food industry<\/li>\n \t<li>Coffee and vending machines<\/li>\n \t<li>Food &amp; Beverage<\/li>\n \t<li>Medical<\/li>\n \t<li>Empty<\/li>\n<\/ul>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1196 size-medium\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-1-300x194.jpg\" alt=\"\" width=\"300\" height=\"194\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-1-300x194.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-1.jpg 375w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1197 size-medium\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-2-300x211.jpg\" alt=\"\" width=\"300\" height=\"211\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-2-300x211.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-2.jpg 356w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1198 size-full\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-3.jpg\" alt=\"\" width=\"272\" height=\"250\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"wp-image-1199 size-full alignleft\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-4.jpg\" alt=\"\" width=\"250\" height=\"250\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-4.jpg 250w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-4-150x150.jpg 150w\" sizes=\"(max-width: 250px) 100vw, 250px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1277 size-medium\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/2020-300x234.jpg\" alt=\"\" width=\"300\" height=\"234\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/2020-300x234.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/2020.jpg 320w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1278 size-medium\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/5000-300x166.jpg\" alt=\"\" width=\"300\" height=\"166\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/5000-300x166.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/5000.jpg 375w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"4\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1404\" aria-expanded=\"false\">Electronic flow regulators<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1404\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1404\" tabindex=\"0\" hidden=\"hidden\"><h2>Electronic flow control valve EFC type<b>\n<\/b><\/h2>\nHigh performance PPSU plastic (polyphenylsulfone)\n\nMotorized flow regulator for dosing liquid and gaseous fluids. In conjunction with the famous ELSA PPSU instant fittings, this valve is mainly used in the food and chemical industry. The control electronics integrated in the valve body allows the needle to be positioned continuously via an analog voltage signal. Through the linear motor stepping technology, a position can be maintained even without electrical voltage.\n<h3>Features<\/h3>\n<ul>\n \t<li>FDA compliant PPSU valve body<\/li>\n \t<li>EPDM or FPM gasket material (FDA compliant)<\/li>\n \t<li>Needle material AISI316L, 1.4404<\/li>\n \t<li>Nominal diameters from DN 0.5 - DN 3<\/li>\n \t<li>ELSA instant fittings, PPSU, for 4 and 6 mm hose.<\/li>\n \t<li>Working pressure PN 8<\/li>\n \t<li>Fluid temperature up to 80 \u00b0 C<\/li>\n \t<li>Integrated control electronics with analog input Us = 24 VDC (power supply) Uc = 0 - 10 VDC (control)<\/li>\n \t<li>Linear stepper motor<\/li>\n<\/ul>\n<h3>Advantages<\/h3>\n<ul>\n \t<li>Optimized retention zones<\/li>\n \t<li>Low hysteresis<\/li>\n \t<li>Easy control<\/li>\n \t<li>Customer-specific features possible (pin or control)<\/li>\n \t<li>NSF Certification<\/li>\n \t<li>Connection via ELSA fitting<\/li>\n<\/ul>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-1223\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/Reg.-flus.-elettr.-1024x584.jpg\" alt=\"\" width=\"800\" height=\"456\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/Reg.-flus.-elettr.-1024x584.jpg 1024w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/Reg.-flus.-elettr.-300x171.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/Reg.-flus.-elettr.-768x438.jpg 768w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/Reg.-flus.-elettr..jpg 1431w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"5\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1405\" aria-expanded=\"false\">Conductivity sensors<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1405\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1405\" tabindex=\"0\" hidden=\"hidden\"><h2>ICS Type Conductivity Sensor<\/h2>\nHigh performance PPSU plastic material\n<h3>Advantages<\/h3>\n<ul>\n \t<li>Optimal price-quality ratio<\/li>\n \t<li>wide measuring range<\/li>\n \t<li>small footprint<\/li>\n \t<li>proven ELSA connection technology<\/li>\n \t<li>thermally neutral measures<\/li>\n \t<li>Integrated temperature sensor<\/li>\n \t<li>integrated correction electronics<\/li>\n<\/ul>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1213 size-full\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/sensore-di-conducib..jpg\" alt=\"\" width=\"951\" height=\"700\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/sensore-di-conducib..jpg 951w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/sensore-di-conducib.-300x221.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/sensore-di-conducib.-768x565.jpg 768w\" sizes=\"(max-width: 951px) 100vw, 951px\" \/><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"6\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1406\" aria-expanded=\"false\">Pressure sensors<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1406\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"6\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1406\" tabindex=\"0\" hidden=\"hidden\"><h2>AVS Pressure sensor type IPS Inline Pressure Sensor<\/h2>\n<h4>Features<\/h4>\n<ul>\n \t<li>PPSU body<\/li>\n \t<li>Seal material FPM or EPDM (FDA compliant)<\/li>\n \t<li>ceramic pressure measuring cell<\/li>\n \t<li>ELSA fittings Connection for 6 or 4 mm hoses<\/li>\n \t<li>Operating pressure up to 16 bar<\/li>\n \t<li>Fluid temperature up to 140 \u00b0 C (NSF approved at 100 \u00b0 C)<\/li>\n \t<li>Power supply 5 VDC<\/li>\n \t<li>0.5-4.5 VDC output signal<\/li>\n \t<li>evaluation system with temperature compensation<\/li>\n \t<li>Measuring range 0-4 or 0-16 bar<\/li>\n<\/ul>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1302\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sensore-di-pressione.jpg\" alt=\"\" width=\"612\" height=\"809\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sensore-di-pressione.jpg 612w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sensore-di-pressione-227x300.jpg 227w\" sizes=\"(max-width: 612px) 100vw, 612px\" \/><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"7\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1407\" aria-expanded=\"false\">Manometers<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1407\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"7\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1407\" tabindex=\"0\" hidden=\"hidden\"><h2>Manometers<\/h2>\n<ul>\n \t<li>Stainless steel pressure gauges<\/li>\n \t<li>Customizable pressure gauges<\/li>\n \t<li>Manometers for boiler room<\/li>\n \t<li>Diaphragm pressure gauges for gas<\/li>\n \t<li>Pressure gauges for dry industrial applications<\/li>\n \t<li>Pressure gauges for industrial applications in glycerine bath<\/li>\n \t<li>Accessories for pressure gauge<\/li>\n<\/ul>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1239 size-thumbnail\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-glicerina-watts-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-glicerina-watts-150x150.jpg 150w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-glicerina-watts-300x300.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-glicerina-watts.jpg 420w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1244 size-thumbnail\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/M1_ABS_100-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/M1_ABS_100-150x150.jpg 150w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/M1_ABS_100-300x300.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/M1_ABS_100-768x768.jpg 768w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/M1_ABS_100.jpg 1000w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1245 size-thumbnail\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-centrale-termica-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-centrale-termica-150x150.jpg 150w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-centrale-termica-300x300.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-centrale-termica-768x768.jpg 768w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-centrale-termica.jpg 1000w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"8\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1408\" aria-expanded=\"false\">Couplings - Quick couplings<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1408\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"8\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1408\" tabindex=\"0\" hidden=\"hidden\"><h2>Quick couplings<\/h2>\n<h3>Applications<\/h3>\nThe peculiar characteristics of these couplings are the ease of cleaning and the very low oil loss in connection and disconnection operations: both determine their uses. They are recommended for applications where the leakage of the fluid constitutes a potential danger for the safety of workers: in addition, the external ring of the female has a safety system to prevent accidental release of the male. Perfectly indicated in industrial plants and in\nany sector of use if you want to avoid both the risk of environmental pollution and the contamination of the hydraulic circuit fluid. They have reduced pressure drops, higher flow rates and higher operating pressures than traditional series. Couplings of this type, generally called \"FLAT FACE\", are used to connect hydraulic tools on operating machines in the construction, road and railway construction and maintenance sectors, in the mining industry and in shipyards and ports.\n<h3>Technical features<\/h3>\nInterchangeability: ISO 16028\nOcclusion: flat valve\nCoupling system: ball crown\nConnection: pushing the male part\nDisconnection: by pulling back the ring\nThreads: BSP - NPTF - BSPT\nSizes: 1\/4 \", 3\/8\", 1\/2 \", 3\/4\", 1 \", 1.\u00bc\", 1.\u00bd \", 2\"\nMaterials:\n<ul>\n \t<li>Female in high carbon steel with some induction hardened parts<\/li>\n \t<li>Male in high carbon content steel, induction hardened<\/li>\n \t<li>Valves in high carbon steel<\/li>\n<\/ul>\nSurface protection: zinc plating and Cr III passivation\nC72 steel springs\nHigh strength balls in 100 C6 steel\nSeals: standard NBR and polyurethane, VITON on request\nAnti-extrusion: PTFE\nOperating temperature: NBR -20 \u00b0 C + 100 \u00b0 C\n\nVITON -15 \u00b0 C + 180 \u00b0 C\n\n<img loading=\"lazy\" decoding=\"async\" class=\"wp-image-508 size-full alignnone\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/giunti-borroni-IR_serieF-1024x663-1.jpg\" alt=\"\" width=\"1024\" height=\"663\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/giunti-borroni-IR_serieF-1024x663-1.jpg 1024w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/giunti-borroni-IR_serieF-1024x663-1-300x194.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/giunti-borroni-IR_serieF-1024x663-1-768x497.jpg 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"9\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1409\" aria-expanded=\"false\">AISI 316L flow regulators<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1409\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"9\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1409\" tabindex=\"0\" hidden=\"hidden\"><h2>Pneumatic flow regulators in stainless steel<\/h2>\nStainless steel flow controllers can be used to regulate the speed of a cylindrical bar as well as a gas flow in environments with high mechanical or chemical constraints. These regulators are suitable for food environments as they prevent contamination of the transported fluids. The design is optimized thanks to the use of smooth external surfaces that simplify cleaning procedures.\n<h3>Features \/ Benefits:<\/h3>\n<h4>Robust<\/h4>\n- Suitable for corrosive environments<br>\n- Excellent mechanical and chemical resistance<br>\n- 100% tested for leakage in production<br>\n- No contamination of transported fluids<br>\n<h4>Optimised Design<\/h4>\n- Smooth outer surfaces for easy cleaning<br>\n- Full compatibility with food environments<br>\n- Easy and precise adjustment<br>\n<h4>Markets<\/h4>\n- Industrial automation<br>\n- Vehicle assembly plants<br>\n- Food and beverage industry<br>\n- Semiconductors<br>\n- Apparel<br>\n- Packaging machinery<br>\n- Railway vehicles<br>\n<h4>Applications<\/h4>\n- Pneumatic cylinder control<br>\n- Adjusts the flow of compressed air at low pressure<br>\nSuitable for corrosive environments<br>\n<h4>Technologies<\/h4>\n\u2022 Regolatore<br>\n- Steel regulator<br>\n- Bidirectional controller<br>\n- One-way controller<br>\n- Swivel fitting outlet<br>\n- Tire checks<br>\n<h4>Technical features<\/h4>\n- Fluids: Compressed air 7822: all compatible fluids depending on the seals used (FKM or PTFE)<br>\n- Materials: 316L stainless steel, FKM<br>\n- Pressure:<br>\n7810-7812: Vacuum at 10 bar<br>\n7820: Vacuum at 16 bar<br>\n7822: Vacuum at 40 bar<br>\n- Temperature:<br>\n7810-7812: 0 \u00b0C to +70 \u00b0C<br>\n7820-7822: -15 \u00b0C to +120 \u00b0C<br>\n\nStandards:<br>\n\n- DI: 2002\/95\/EC (RoHS)<br>\n- RG: 1907\/2006 (REACH)<br>\n- OF: 97\/23\/CE (PED)<br>\n- RG: External components: 21CFR (FDA)<br>\n- RG: External Components: 1935\/2004\/EC<br>\n\nProduct types:<br>\n\n- Exhaust flow regulator, BSPP male\/female and metric threads<br>\n- Bidirectional flow controller, BSPP male\/female and metric threads<br>\n- Unidirectional in-line flow controller, BSPP female thread<br>\n- In-line bidirectional flow controller, BSPP female thread<br>\n\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1266\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Regolatori-di-flusso.jpg\" alt=\"\" width=\"841\" height=\"852\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Regolatori-di-flusso.jpg 841w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Regolatori-di-flusso-296x300.jpg 296w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Regolatori-di-flusso-768x778.jpg 768w\" sizes=\"(max-width: 841px) 100vw, 841px\" \/><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"10\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-14010\" aria-expanded=\"false\">Non-return valves in 316L stainless steel<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-14010\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"10\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-14010\" tabindex=\"0\" hidden=\"hidden\"><h2>Non-return valves in 316L stainless steel<\/h2>\nFunction: unidirectional passage of the fluid\n<ul>\n \t<li>Stainless steel<\/li>\n \t<li>Pressure: 0.5 to 40 bar<\/li>\n \t<li>Temperature: -20 \u00b0 C to + 180 \u00b0 C<\/li>\n \t<li>ON: 10 mm to 25 mm<\/li>\n \t<li>Threads: BSPP, NPT<\/li>\n \t<li>Standards:\n<ul>\n \t<li>Regulation: 2002\/95 \/ EC (RoHS)<\/li>\n \t<li>RG: 1907\/2006 (REACH)<\/li>\n \t<li>Directive: 97\/23 \/ EC (PED)<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1258\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Valvola-di-non-ritorno.jpg\" alt=\"\" width=\"1017\" height=\"800\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Valvola-di-non-ritorno.jpg 1017w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Valvola-di-non-ritorno-300x236.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Valvola-di-non-ritorno-768x604.jpg 768w\" sizes=\"(max-width: 1017px) 100vw, 1017px\" \/><\/li>\n<\/ul>\n<\/li>\n<\/ul><\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-54ddd3d elementor-hidden-desktop elementor-hidden-tablet elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"54ddd3d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-3b854eb\" data-id=\"3b854eb\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d41745f elementor-widget elementor-widget-toggle\" data-id=\"d41745f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h2 id=\"elementor-tab-title-2221\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-2221\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-angle-down\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-angle-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Temperature probes<\/a>\n\t\t\t\t\t<\/h2>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2221\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-2221\">\n<h2>ITS Inline Temperature Sensor<\/h2>\nFEATURES\n\u2022 PPSU body\n\u2022 Sealing material FPM or EPDM (FDA compliant)\n\u2022 Al2 O3 probe material\n\u2022 Types of existing sensor: Pt 100; NTC 10k; NTC 47k,\n\u2022 Other types of sensors and thermocouples on request\n\u2022 Connection of ELSA fittings for 6 or 4mm tube\n\u2022 Working pressure up to PN 20\n\u2022 Fluid temperature up to 135 \u00b0 C (NSF approved at 100 \u00b0 C)\n\n<img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-1303\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sonda-di-temperatura.jpg\" alt=\"\" width=\"589\" height=\"870\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sonda-di-temperatura.jpg 589w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sonda-di-temperatura-203x300.jpg 203w\" sizes=\"(max-width: 589px) 100vw, 589px\" \/><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h2 id=\"elementor-tab-title-2222\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-2222\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-angle-down\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-angle-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Smartflow<\/a>\n\t\t\t\t\t<\/h2>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2222\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-2222\"><h2>Smartflow<\/h2>\nPump with an innovative concept\n\n<a href=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min.png\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-2632 size-medium\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-300x213.png\" alt=\"AVS Roemer Smartflow\" width=\"300\" height=\"213\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-300x213.png 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-1024x726.png 1024w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-768x545.png 768w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-1536x1090.png 1536w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-18x12.png 18w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-1320x936.png 1320w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min-600x426.png 600w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-min.png 1920w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a> <a href=\"https:\/\/www.fluidotecnika.com\/en\/smartflow-2\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"alignleft wp-image-2633 size-medium\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2-300x214.png\" alt=\"AVS Roemer Smartflow\" width=\"300\" height=\"214\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2-300x214.png 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2-1024x732.png 1024w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2-768x549.png 768w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2-18x12.png 18w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2-1320x943.png 1320w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2-600x429.png 600w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2021\/11\/smartflow-2.png 1440w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a>\n<h3>Features<\/h3>\n<ul>\n \t<li>Excellent chemical resistance<\/li>\n \t<li>Drive with specially developed BLDC motor<\/li>\n \t<li>Absence of dead spaces that would encourage the formation of unwanted bacteria<\/li>\n \t<li>Prevents microbiological buildup and growth<\/li>\n \t<li>Maintenance-free, durable, reliable<\/li>\n \t<li>Tight seal ensures wear-free operation and prevents leakage<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<ul>\n \t<li>Machines and plants for food beverages<\/li>\n \t<li>Medical industry<\/li>\n \t<li>Industry<\/li>\n<\/ul>\n<a href=\"https:\/\/www.avs-roemer.de\/media\/service\/produktkatalog-broschueren\/AVS_R%C3%B6mer_Produktflyer_Au%C3%9Fenzahnradpumpe_smartflow.pdf\" target=\"_blank\" rel=\"noopener\"><strong>DOWNLOAD DATA SHEET<\/strong><\/a><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h2 id=\"elementor-tab-title-2223\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-2223\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-angle-down\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-angle-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">CW510L<\/a>\n\t\t\t\t\t<\/h2>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2223\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-2223\"><h2>Components in CW510L low lead brass<\/h2><h3>Main advantages<\/h3><ul><li>NSF 169 and NSF 61, 1935\/2004 \/ CE, DM 174<\/li><li>Instant connection and disconnection<\/li><li>Full passage and vacuum seal thanks to shaped gaskets<\/li><li>Two types of threads, BSPP, BSPT<\/li><li>Wide range available to satisfy the most demanding installations<\/li><li>Silicon Free<\/li><\/ul><h3>Applications<\/h3><ul><li>Agri-food industry<\/li><li>Coffee and vending machines<\/li><li>Food &amp; Beverage<\/li><li>Medical<\/li><li>Empty<\/li><\/ul><p><div id='gallery-1' class='gallery galleryid-301 gallery-columns-2 gallery-size-thumbnail'><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-1.jpg'><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-1-150x150.jpg\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-2.jpg'><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-2-150x150.jpg\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-3.jpg'><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-3-150x150.jpg\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-4.jpg'><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-4-150x150.jpg\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-4-150x150.jpg 150w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/CW510L-4.jpg 250w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/2020.jpg'><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/2020-150x150.jpg\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" \/><\/a>\n\t\t\t<\/div><\/figure><figure class='gallery-item'>\n\t\t\t<div class='gallery-icon landscape'>\n\t\t\t\t<a href='https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/5000.jpg'><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/5000-150x150.jpg\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" \/><\/a>\n\t\t\t<\/div><\/figure>\n\t\t<\/div>\n<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h2 id=\"elementor-tab-title-2224\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-2224\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-angle-down\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-angle-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Electronic flow regulators<\/a>\n\t\t\t\t\t<\/h2>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2224\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-2224\"><h2>Electronic flow control valve EFC type<b>\n<\/b><\/h2>\nHigh performance PPSU plastic (polyphenylsulfone)\n\nMotorized flow regulator for dosing liquid and gaseous fluids. In conjunction with the famous ELSA PPSU instant fittings, this valve is mainly used in the food and chemical industry. The control electronics integrated in the valve body allows the needle to be positioned continuously via an analog voltage signal. Through the linear motor stepping technology, a position can be maintained even without electrical voltage.\n<h3>Features<\/h3>\n<ul>\n \t<li>FDA compliant PPSU valve body<\/li>\n \t<li>EPDM or FPM gasket material (FDA compliant)<\/li>\n \t<li>Needle material AISI316L, 1.4404<\/li>\n \t<li>Nominal diameters from DN 0.5 - DN 3<\/li>\n \t<li>ELSA instant fittings, PPSU, for 4 and 6 mm hose.<\/li>\n \t<li>Working pressure PN 8<\/li>\n \t<li>Fluid temperature up to 80 \u00b0 C<\/li>\n \t<li>Integrated control electronics with analog input Us = 24 VDC (power supply) Uc = 0 - 10 VDC (control)<\/li>\n \t<li>Linear stepper motor<\/li>\n<\/ul>\n<h3>Advantages<\/h3>\n<ul>\n \t<li>Optimized retention zones<\/li>\n \t<li>Low hysteresis<\/li>\n \t<li>Easy control<\/li>\n \t<li>Customer-specific features possible (pin or control)<\/li>\n \t<li>NSF Certification<\/li>\n \t<li>Connection via ELSA fitting<\/li>\n<\/ul>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-1223\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/Reg.-flus.-elettr.-1024x584.jpg\" alt=\"\" width=\"800\" height=\"456\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/Reg.-flus.-elettr.-1024x584.jpg 1024w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/Reg.-flus.-elettr.-300x171.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/Reg.-flus.-elettr.-768x438.jpg 768w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/Reg.-flus.-elettr..jpg 1431w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h2 id=\"elementor-tab-title-2225\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-2225\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-angle-down\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-angle-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Conductivity sensors<\/a>\n\t\t\t\t\t<\/h2>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2225\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-2225\"><h2>ICS Type Conductivity Sensor<\/h2>\nHigh performance PPSU plastic material\n<h3>Advantages<\/h3>\n<ul>\n \t<li>Optimal price-quality ratio<\/li>\n \t<li>wide measuring range<\/li>\n \t<li>small footprint<\/li>\n \t<li>proven ELSA connection technology<\/li>\n \t<li>thermally neutral measures<\/li>\n \t<li>Integrated temperature sensor<\/li>\n \t<li>integrated correction electronics<\/li>\n<\/ul>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1213 size-full\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/sensore-di-conducib..jpg\" alt=\"\" width=\"951\" height=\"700\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/sensore-di-conducib..jpg 951w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/sensore-di-conducib.-300x221.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/sensore-di-conducib.-768x565.jpg 768w\" sizes=\"(max-width: 951px) 100vw, 951px\" \/><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h2 id=\"elementor-tab-title-2226\" class=\"elementor-tab-title\" data-tab=\"6\" role=\"button\" aria-controls=\"elementor-tab-content-2226\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-angle-down\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-angle-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Pressure sensors<\/a>\n\t\t\t\t\t<\/h2>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2226\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"6\" role=\"region\" aria-labelledby=\"elementor-tab-title-2226\"><h2>AVS Pressure sensor type IPS Inline Pressure Sensor<\/h2>\n<h4>Features<\/h4>\n<ul>\n \t<li>PPSU body<\/li>\n \t<li>Seal material FPM or EPDM (FDA compliant)<\/li>\n \t<li>ceramic pressure measuring cell<\/li>\n \t<li>ELSA fittings Connection for 6 or 4 mm hoses<\/li>\n \t<li>Operating pressure up to 16 bar<\/li>\n \t<li>Fluid temperature up to 140 \u00b0 C (NSF approved at 100 \u00b0 C)<\/li>\n \t<li>Power supply 5 VDC<\/li>\n \t<li>0.5-4.5 VDC output signal<\/li>\n \t<li>evaluation system with temperature compensation<\/li>\n \t<li>Measuring range 0-4 or 0-16 bar<\/li>\n<\/ul>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1302\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sensore-di-pressione.jpg\" alt=\"\" width=\"612\" height=\"809\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sensore-di-pressione.jpg 612w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sensore-di-pressione-227x300.jpg 227w\" sizes=\"(max-width: 612px) 100vw, 612px\" \/><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h2 id=\"elementor-tab-title-2227\" class=\"elementor-tab-title\" data-tab=\"7\" role=\"button\" aria-controls=\"elementor-tab-content-2227\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-angle-down\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-angle-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Manometers<\/a>\n\t\t\t\t\t<\/h2>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2227\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"7\" role=\"region\" aria-labelledby=\"elementor-tab-title-2227\"><h2>Manometers<\/h2>\n<ul>\n \t<li>Stainless steel pressure gauges<\/li>\n \t<li>Customizable pressure gauges<\/li>\n \t<li>Manometers for boiler room<\/li>\n \t<li>Diaphragm pressure gauges for gas<\/li>\n \t<li>Pressure gauges for dry industrial applications<\/li>\n \t<li>Pressure gauges for industrial applications in glycerine bath<\/li>\n \t<li>Accessories for pressure gauge<\/li>\n<\/ul>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1239 size-thumbnail\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-glicerina-watts-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-glicerina-watts-150x150.jpg 150w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-glicerina-watts-300x300.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-glicerina-watts.jpg 420w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1244 size-thumbnail\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/M1_ABS_100-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/M1_ABS_100-150x150.jpg 150w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/M1_ABS_100-300x300.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/M1_ABS_100-768x768.jpg 768w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/M1_ABS_100.jpg 1000w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-1245 size-thumbnail\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-centrale-termica-150x150.jpg\" alt=\"\" width=\"150\" height=\"150\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-centrale-termica-150x150.jpg 150w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-centrale-termica-300x300.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-centrale-termica-768x768.jpg 768w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/manometro-centrale-termica.jpg 1000w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h2 id=\"elementor-tab-title-2228\" class=\"elementor-tab-title\" data-tab=\"8\" role=\"button\" aria-controls=\"elementor-tab-content-2228\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-angle-down\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-angle-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Couplings - Quick couplings<\/a>\n\t\t\t\t\t<\/h2>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2228\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"8\" role=\"region\" aria-labelledby=\"elementor-tab-title-2228\"><h2>Quick couplings<\/h2>\n<h3>Applications<\/h3>\nThe peculiar characteristics of these couplings are the ease of cleaning and the very low oil loss in connection and disconnection operations: both determine their uses. They are recommended for applications where the leakage of the fluid constitutes a potential danger for the safety of workers: in addition, the external ring of the female has a safety system to prevent accidental release of the male. Perfectly indicated in industrial plants and in\nany sector of use if you want to avoid both the risk of environmental pollution and the contamination of the hydraulic circuit fluid. They have reduced pressure drops, higher flow rates and higher operating pressures than traditional series. Couplings of this type, generally called \"FLAT FACE\", are used to connect hydraulic tools on operating machines in the construction, road and railway construction and maintenance sectors, in the mining industry and in shipyards and ports.\n<h3>Technical features<\/h3>\nInterchangeability: ISO 16028\nOcclusion: flat valve\nCoupling system: ball crown\nConnection: pushing the male part\nDisconnection: by pulling back the ring\nThreads: BSP - NPTF - BSPT\nSizes: 1\/4 \", 3\/8\", 1\/2 \", 3\/4\", 1 \", 1.\u00bc\", 1.\u00bd \", 2\"\nMaterials:\n<ul>\n \t<li>Female in high carbon steel with some induction hardened parts<\/li>\n \t<li>Male in high carbon content steel, induction hardened<\/li>\n \t<li>Valves in high carbon steel<\/li>\n<\/ul>\nSurface protection: zinc plating and Cr III passivation\nC72 steel springs\nHigh strength balls in 100 C6 steel\nSeals: standard NBR and polyurethane, VITON on request\nAnti-extrusion: PTFE\nOperating temperature: NBR -20 \u00b0 C + 100 \u00b0 C\n\nVITON -15 \u00b0 C + 180 \u00b0 C\n\n<img loading=\"lazy\" decoding=\"async\" class=\"wp-image-508 size-full alignnone\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/giunti-borroni-IR_serieF-1024x663-1.jpg\" alt=\"\" width=\"1024\" height=\"663\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/giunti-borroni-IR_serieF-1024x663-1.jpg 1024w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/giunti-borroni-IR_serieF-1024x663-1-300x194.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/11\/giunti-borroni-IR_serieF-1024x663-1-768x497.jpg 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h2 id=\"elementor-tab-title-2229\" class=\"elementor-tab-title\" data-tab=\"9\" role=\"button\" aria-controls=\"elementor-tab-content-2229\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-angle-down\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-angle-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">AISI 316L flow regulators<\/a>\n\t\t\t\t\t<\/h2>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2229\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"9\" role=\"region\" aria-labelledby=\"elementor-tab-title-2229\"><h2>Pneumatic flow regulators in stainless steel<\/h2>\nStainless steel flow controllers can be used to regulate the speed of a cylindrical bar as well as a gas flow in environments with high mechanical or chemical constraints. These regulators are suitable for food environments as they prevent contamination of the transported fluids. The design is optimized thanks to the use of smooth external surfaces that simplify cleaning procedures.\n<h4>Features \/ Benefits:<\/h4>\n<h4>Robust<\/h4>\n\u2022 Suitable for corrosive environments\n\u2022 Excellent mechanical and chemical resistance\n\u2022 100% tested for production losses\n\u2022 No contamination of the transported fluids\n<h4>Optimised Design<\/h4>\n\u2022 Smooth exterior surfaces for easy cleaning\n\u2022 Full compatibility with food environments\n\u2022 Simple and precise adjustment\n<h4>Markets<\/h4>\n\u2022 Industrial automation\n\u2022 Vehicle assembly plants\n\u2022 Food and beverage industry\n\u2022 Semiconductors\n\u2022 Clothing\n\u2022 Packaging machinery\n\u2022 Railway vehicles\n<h4>Applications<\/h4>\n\u2022 Checking the pneumatic cylinder\n\u2022 Low pressure compressed air flow adjustment\n\u2022 Suitable for corrosive environments\n<h4>Technologies<\/h4>\n\u2022 Regulator\n\u2022 Steel regulator\n\u2022 Bidirectional regulator\n\u2022 Unidirectional regulator\n\u2022 Swivel fitting outlet\n\u2022 Pneumatic controls\n<h4>Technical features<\/h4>\n\u2022 Fluids: Compressed air 7822: all compatible fluids based on the seals used (FKM or PTFE)\n\u2022 Materials: 316L stainless steel, FKM\n\u2022 Pressure:\n7810-7812: Vacuum at 10 bar\n7820: Vacuum at 16 bar\n7822: Vacuum at 40 bar\n\u2022 Temperature:\n7810-7812: 0 \u00b0 C to +70 \u00b0 C\n7820-7822: -15 \u00b0 C to +120 \u00b0 C\n\nRegulations:\n\n\u2022 DI: 2002\/95 \/ CE (RoHS)\n\u2022 RG: 1907\/2006 (REACH)\n\u2022 DI: 97\/23 \/ CE (PED)\n\u2022 RG: External components: 21CFR (FDA)\n\u2022 RG: External components: 1935\/2004 \/ CE\n\nProduct Types:\n\n\u2022 Exhaust flow regulator, male \/ female BSPP and metric thread\n\u2022 Bidirectional flow regulator, male \/ female BSPP and metric thread\n\u2022 In-line unidirectional flow regulator, BSPP female thread\n\u2022 In-line bidirectional flow regulator, BSPP female thread\n\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1266\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Regolatori-di-flusso.jpg\" alt=\"\" width=\"841\" height=\"852\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Regolatori-di-flusso.jpg 841w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Regolatori-di-flusso-296x300.jpg 296w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Regolatori-di-flusso-768x778.jpg 768w\" sizes=\"(max-width: 841px) 100vw, 841px\" \/><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<h2 id=\"elementor-tab-title-22210\" class=\"elementor-tab-title\" data-tab=\"10\" role=\"button\" aria-controls=\"elementor-tab-content-22210\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><i class=\"fas fa-angle-down\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><i class=\"elementor-toggle-icon-opened fas fa-angle-up\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Non-return valves in 316L stainless steel<\/a>\n\t\t\t\t\t<\/h2>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-22210\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"10\" role=\"region\" aria-labelledby=\"elementor-tab-title-22210\"><h2>Non-return valves in 316L stainless steel<\/h2>\nFunction: unidirectional passage of the fluid\n<ul>\n \t<li>Stainless steel<\/li>\n \t<li>Pressure: 0.5 to 40 bar<\/li>\n \t<li>Temperature: -20 \u00b0 C to + 180 \u00b0 C<\/li>\n \t<li>ON: 10 mm to 25 mm<\/li>\n \t<li>Threads: BSPP, NPT<\/li>\n \t<li>Standards:\n<ul>\n \t<li>Regulation: 2002\/95 \/ EC (RoHS)<\/li>\n \t<li>RG: 1907\/2006 (REACH)<\/li>\n \t<li>Directive: 97\/23 \/ EC (PED)<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1258\" src=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Valvola-di-non-ritorno.jpg\" alt=\"\" width=\"1017\" height=\"800\" srcset=\"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Valvola-di-non-ritorno.jpg 1017w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Valvola-di-non-ritorno-300x236.jpg 300w, https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Valvola-di-non-ritorno-768x604.jpg 768w\" sizes=\"(max-width: 1017px) 100vw, 1017px\" \/><\/li>\n<\/ul>\n<\/li>\n<\/ul><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Sensori di temperatura, di pressione, di conduttivit\u00e0, di conducibilit\u00e0, per macchine utensili ed impianti in ambito alimentare, farmaceutico, chimico ed in ogni settore dell\u2019automazione. Sonde di temperatura Smartflow CW510L Regolatori elettronici di flusso Sensori di conducibilit\u00e0 Sensori di pressione Manometri Giunti &#8211; Innesti rapidi Regolatori di flusso AISI 316L Valvole di non ritorno in acciaio [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-301","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Componenti industriali per controllo fluidi &#183; Fluidotecnika<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.fluidotecnika.com\/en\/accessori\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Componenti industriali per controllo fluidi &#183; Fluidotecnika\" \/>\n<meta property=\"og:description\" content=\"Sensori di temperatura, di pressione, di conduttivit\u00e0, di conducibilit\u00e0, per macchine utensili ed impianti in ambito alimentare, farmaceutico, chimico ed in ogni settore dell\u2019automazione. Sonde di temperatura Smartflow CW510L Regolatori elettronici di flusso Sensori di conducibilit\u00e0 Sensori di pressione Manometri Giunti &#8211; Innesti rapidi Regolatori di flusso AISI 316L Valvole di non ritorno in acciaio [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.fluidotecnika.com\/en\/accessori\/\" \/>\n<meta property=\"og:site_name\" content=\"Fluidotecnika\" \/>\n<meta property=\"article:modified_time\" content=\"2022-06-13T13:41:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/i0.wp.com\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sonda-di-temperatura.jpg?resize=589%2C870&#038;ssl=1\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"20 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.fluidotecnika.com\\\/accessori\\\/\",\"url\":\"https:\\\/\\\/www.fluidotecnika.com\\\/accessori\\\/\",\"name\":\"Componenti industriali per controllo fluidi &#183; Fluidotecnika\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.fluidotecnika.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.fluidotecnika.com\\\/accessori\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.fluidotecnika.com\\\/accessori\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/i0.wp.com\\\/www.fluidotecnika.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/Sonda-di-temperatura.jpg?resize=589%2C870&#038;ssl=1\",\"datePublished\":\"2020-10-27T11:44:41+00:00\",\"dateModified\":\"2022-06-13T13:41:34+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.fluidotecnika.com\\\/accessori\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.fluidotecnika.com\\\/accessori\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.fluidotecnika.com\\\/accessori\\\/#primaryimage\",\"url\":\"https:\\\/\\\/i0.wp.com\\\/www.fluidotecnika.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/Sonda-di-temperatura.jpg?resize=589%2C870&#038;ssl=1\",\"contentUrl\":\"https:\\\/\\\/i0.wp.com\\\/www.fluidotecnika.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/Sonda-di-temperatura.jpg?resize=589%2C870&#038;ssl=1\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.fluidotecnika.com\\\/accessori\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.fluidotecnika.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Componenti per l&#8217;industria\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.fluidotecnika.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.fluidotecnika.com\\\/en\\\/\",\"name\":\"Fluidotecnika\",\"description\":\"Soluzioni industriali in controllo dei fluidi\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.fluidotecnika.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.fluidotecnika.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.fluidotecnika.com\\\/en\\\/#organization\",\"name\":\"Fluidotecnika Srl\",\"url\":\"https:\\\/\\\/www.fluidotecnika.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.fluidotecnika.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.fluidotecnika.com\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/Logo-fluidotecnika-colori-2.png\",\"contentUrl\":\"https:\\\/\\\/www.fluidotecnika.com\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/Logo-fluidotecnika-colori-2.png\",\"width\":1920,\"height\":1053,\"caption\":\"Fluidotecnika Srl\"},\"image\":{\"@id\":\"https:\\\/\\\/www.fluidotecnika.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/fluidotecnika-srl\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Componenti industriali per controllo fluidi &#183; Fluidotecnika","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.fluidotecnika.com\/en\/accessori\/","og_locale":"en_GB","og_type":"article","og_title":"Componenti industriali per controllo fluidi &#183; Fluidotecnika","og_description":"Sensori di temperatura, di pressione, di conduttivit\u00e0, di conducibilit\u00e0, per macchine utensili ed impianti in ambito alimentare, farmaceutico, chimico ed in ogni settore dell\u2019automazione. Sonde di temperatura Smartflow CW510L Regolatori elettronici di flusso Sensori di conducibilit\u00e0 Sensori di pressione Manometri Giunti &#8211; Innesti rapidi Regolatori di flusso AISI 316L Valvole di non ritorno in acciaio [&hellip;]","og_url":"https:\/\/www.fluidotecnika.com\/en\/accessori\/","og_site_name":"Fluidotecnika","article_modified_time":"2022-06-13T13:41:34+00:00","og_image":[{"url":"https:\/\/i0.wp.com\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sonda-di-temperatura.jpg?resize=589%2C870&#038;ssl=1","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Estimated reading time":"20 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.fluidotecnika.com\/accessori\/","url":"https:\/\/www.fluidotecnika.com\/accessori\/","name":"Componenti industriali per controllo fluidi &#183; Fluidotecnika","isPartOf":{"@id":"https:\/\/www.fluidotecnika.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.fluidotecnika.com\/accessori\/#primaryimage"},"image":{"@id":"https:\/\/www.fluidotecnika.com\/accessori\/#primaryimage"},"thumbnailUrl":"https:\/\/i0.wp.com\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sonda-di-temperatura.jpg?resize=589%2C870&#038;ssl=1","datePublished":"2020-10-27T11:44:41+00:00","dateModified":"2022-06-13T13:41:34+00:00","breadcrumb":{"@id":"https:\/\/www.fluidotecnika.com\/accessori\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.fluidotecnika.com\/accessori\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.fluidotecnika.com\/accessori\/#primaryimage","url":"https:\/\/i0.wp.com\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sonda-di-temperatura.jpg?resize=589%2C870&#038;ssl=1","contentUrl":"https:\/\/i0.wp.com\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/12\/Sonda-di-temperatura.jpg?resize=589%2C870&#038;ssl=1"},{"@type":"BreadcrumbList","@id":"https:\/\/www.fluidotecnika.com\/accessori\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.fluidotecnika.com\/"},{"@type":"ListItem","position":2,"name":"Componenti per l&#8217;industria"}]},{"@type":"WebSite","@id":"https:\/\/www.fluidotecnika.com\/en\/#website","url":"https:\/\/www.fluidotecnika.com\/en\/","name":"Fluidotecnika","description":"Soluzioni industriali in controllo dei fluidi","publisher":{"@id":"https:\/\/www.fluidotecnika.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.fluidotecnika.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.fluidotecnika.com\/en\/#organization","name":"Fluidotecnika Srl","url":"https:\/\/www.fluidotecnika.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.fluidotecnika.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/10\/Logo-fluidotecnika-colori-2.png","contentUrl":"https:\/\/www.fluidotecnika.com\/wp-content\/uploads\/2020\/10\/Logo-fluidotecnika-colori-2.png","width":1920,"height":1053,"caption":"Fluidotecnika Srl"},"image":{"@id":"https:\/\/www.fluidotecnika.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/fluidotecnika-srl\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.fluidotecnika.com\/en\/wp-json\/wp\/v2\/pages\/301","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fluidotecnika.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.fluidotecnika.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.fluidotecnika.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fluidotecnika.com\/en\/wp-json\/wp\/v2\/comments?post=301"}],"version-history":[{"count":0,"href":"https:\/\/www.fluidotecnika.com\/en\/wp-json\/wp\/v2\/pages\/301\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.fluidotecnika.com\/en\/wp-json\/wp\/v2\/media?parent=301"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}